IronSphere Product Pack - CA7 TSS

IronSphere Product Pack - CA7 TSS

IronSphere Product Pack - CA7  Workflow Automation (TSS)  ** Temporary **
Product Pack          : Package CA7 checks for Top Secret.
License                    : Z/OSCA7
Description             : CA& Workflow Automation checks for TSS and native CA7 security. 
Instructions             : 
  1. Download the attached file to your workstation.
  2. Upload file to the mainframe as Binary, FB, 80, 3120.
  3. Using the administrator menu of the web interface generate a license request file and send it to support@securiteam.co.il, or open a ticket in customer care.
  4. Install the license received from support.
  5. Update <prefix>.SQIFPARM(QIFCHKxx) with check definitions described in section Parmlib update. 
  6. Update check QIFINSTL with the DSNAME of the file uploaded in step 1. Use the following command or update via SDSF/CK:  f hzsproc,update,check=(*,mvr_INS_TAL_ER),PARM('QIF.PPQISHMC.XMI') 
  7. Verify installation by reviewing messages in SYSLOG and debug file (if DEBUG is set). 

Parmlib  update      :   Place the below definitions in <prefix>.SQIFPARM(QIFCHKxx).
                                     Note: The last check is defined with a comma!

      {                                                                  
       "NAME":"QISCA700",                                             
       "CKNAME":"MVT_CA7_000_00",                                     
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                 
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation Installation data sets must  
                be properly protected.                                
                "                                                     
       },                                                             
   {                                                                  
       "NAME":"QISCA701",                                             
       "CKNAME":"MVT_CA7_010_00",                                     
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                 
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation datasets must be properly    
                protected.                                            
                "                                                     
       },                                                             
   {                                                                  
       "NAME":"QISCA702",                                              
       "CKNAME":"MVT_CA7_020_00",                                      
       "ESM":"TSS",                                                    
       "PARM":" ",                                                     
       "STRTHH":"06",                                                  
       "STRTMM":"00",                                                  
       "INTERVAL":"12",                                                
       "STATUS":"ACTIVE",                                              
       "TITLE":"CA-7 Workload Automation started Task name             
                will be properly defined to system ACP.                
                "                                                      
       },                                                              
   {                                                                   
       "NAME":"QISCA703",                                              
       "CKNAME":"MVT_CA7_030_00",                                      
       "ESM":"TSS",                                                    
       "PARM":" ",                                                     
       "STRTHH":"06",                                                  
       "STRTMM":"00",                                                  
       "INTERVAL":"12",                                                
       "STATUS":"ACTIVE",                                              
       "TITLE":"CA-7 Workload Automation started task will be properly 
                defined to the Started Task Tablee acid for top-secret.
                "                                                      
       },                                                              
   {                                                                   
       "NAME":"QISCA704",                                              
       "CKNAME":"MVT_CA7_040_00",                                      
       "ESM":"TSS",                                                    
       "PARM":" ",                                                     
       "STRTHH":"06",                                                  
       "STRTMM":"00",                                                  
       "INTERVAL":"12",                                                
       "STATUS":"ACTIVE",                                              
       "TITLE":"CA-7 Workload Automation will be properly defined to   
                the Facility Matrix Table.                             
                "                                                      
       },                                                              
   {                                                                   
       "NAME":"QISCA705",                                              
       "CKNAME":"MVT_CA7_050_00",                                      
       "ESM":"TSS",                                                    
       "PARM":" ",                                                     
       "STRTHH":"06",                                                  
       "STRTMM":"00",                                                  
       "INTERVAL":"12",                                                
       "STATUS":"ACTIVE",                                              
       "TITLE":"CA-7 Workload Automation configuration/parameter       
                values are not specified properly.                     
                "                                                      
       },                                                              
   {                                                                   
       "NAME":"QISCA706",                                              
       "CKNAME":"MVT_CA7_060_00",                                      
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                 
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation version is not supported.    
                "                                                     
       },                                                             
   {                                                                  
       "NAME":"QISCA707",                                             
       "CKNAME":"MVT_CA7_070_00",                                     
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                 
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation commands are not properly    
                protected.                                            
                "                                                     
       },                                                             
   {                                                                  
       "NAME":"QISCA708",                                             
       "CKNAME":"MVT_CA7_080_00",                                     
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                
       "STRTMM":"00",                                                
       "INTERVAL":"12",                                              
       "STATUS":"ACTIVE",                                            
       "TITLE":"CA-7 Workload Automation commands are not properly   
                protected.                                           
                "                                                    
       },                                                            
   {                                                                 
       "NAME":"QISCA709",                                            
       "CKNAME":"MVT_CA7_090_00",                                    
       "ESM":"TSS",                                                  
       "PARM":" ",                                                   
       "STRTHH":"06",                                                
       "STRTMM":"00",                                                
       "INTERVAL":"12",                                              
       "STATUS":"ACTIVE",                                            
       "TITLE":"CA-7 Workload Automation commands are not properly   
                protected.                                           
                "                                                    
       },                                                            
   {                                                                 
       "NAME":"QISCA710",                                            
       "CKNAME":"MVT_CA7_100_00",                                    
       "ESM":"TSS",                                                  
       "PARM":" ",                                                   
       "STRTHH":"06",                                                
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation commands are not properly    
                protected.                                            
                "                                                     
       },                                                             
   {                                                                  
       "NAME":"QISCA711",                                             
       "CKNAME":"MVT_CA7_110_00",                                     
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                 
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation commands are not properly    
                protected.                                            
                "                                                     
       },                                                             
   {                                                                  
       "NAME":"QISCA712",                                             
       "CKNAME":"MVT_CA7_120_00",                                     
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                 
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation commands are not properly    
                protected.                                            
                "                                                     
       },                                                             
   {                                                                  
       "NAME":"QISCA713",                                             
       "CKNAME":"MVT_CA7_130_00",                                     
       "ESM":"TSS",                                                   
       "PARM":" ",                                                    
       "STRTHH":"06",                                                 
       "STRTMM":"00",                                                 
       "INTERVAL":"12",                                               
       "STATUS":"ACTIVE",                                             
       "TITLE":"CA-7 Workload Automation CA Workload Automation UID', 
                'resources are not protected in accordance with',     
                'security requirements.'                              
                "                                                     
       },